CDD4B4  Carbon Dioxide Sensor, Dual Beam, Outside, Analog Op, unheated

CDD4B4 Carbon Dioxide Sensor, Dual Beam, Outside, Analog Op, unheated

£599.00
£599.00
(-0%)
(Price excludes VAT)
Outside Carbon Dioxide CO2 Transmitter with Analog Outputs. 0-20000ppm Dual Beam sensor. Unheated enclosure
Model: CDD4B4
Subtotal: £599.00

Free Shipping Free standard shipping on orders over £500

Free Returns 30 Day Money Back Guarantee
icon

UK company

icon

40 years experience

icon

Talk to our expert engineers

CDD4B4  Carbon Dioxide Sensor, Dual Beam, Outside, Analog Op, unheated

CDD4B4 Carbon Dioxide Sensor, Dual Beam, Outside, Analog Op, unheated

£599.00

CDD4B4 Carbon Dioxide Sensor, Dual Beam, Outside, Analog Op, unheated

£599.00

The CDD4 Series CO2 transmitter uses a highly accurate and reliable Non-dispersive Infrared (NDIR) with state-of-the-art digital linearization and temperature compensated circuitry in an outside mount to detect CO2 levels and provides a linear analog signal output of 4-20 mA, 0-5 or 0-10 Vdc signals. The CDD4 is available with a range 0-20,000 ppm (Dual-channel). Parameters are set up via the concealed LCD display. Various precision thermistors or RTD’s are also available as an optional temperature output.

  • Menu driven set-up
  • 20,000 (Dual-channel) PPM CO2 range
  • Patented self-calibration algorithm
  • Guaranteed 5 year calibration interval
  • Optional Temperature Sensor Outputs
  • Easily field calibrated
  • Range....................................0 - 2000 ppm standard,
    programmable span from 2000 to 20,000 ppm
  • Accuracy ..............................±75 PPM or 10% of reading (whichever is greater)
  • Sensor.......................................Dual Channel Non-Dispersive Infrared (NDIR), diffusion sampling
  • Sensor Coverage Area ....100 m² (1000 ft²) typical
  • Temp. Dependence .........0.2% FS per °C
  • Stability................................< 5 % FS over life of sensor
  • Sensor Life Span ...............15 years typical
  • Press. Dependence ..........0.13% of reading per mm Hg
  • Altitude Correction ..........Programmable from 0-5000 ft via keypad
  • Response Time ..................<2 minutes for 90% step change typical
  • Warm-up Time...................<2 minutes
  • Power Supply.....................20-28 Vac/dc (non-isolated half-wave rectified)
  • Output Signals...................4-20 mA active (sourcing), 0-5 Vdc or 0-10 Vdc (field selectable)
  • Consumption.....................Heated: 1.0 A max @ 24 Vdc 1.1 A max @ 24 Vac
    Unheated: 100 mA max @ 24 Vdc 185 mA max @ 24 Vac
  • Output Drive Capability.....Current: 550 ohms max
    Voltage: 10 Kohm min
  • Output Resolution ...........10 bit PWM
  • Protection Circuitry..........Reverse voltage & overvoltage protected
  • Operation Conditions .....Heated: -40Ëš- 50°C (-40Ëš-122°F)
    Unheated: 0Ëš- 50°C (32Ëš-122°F)
    0-95% RH non-condensing
  • Wiring Connections.........Screw terminal block (14 to 22 AWG)
  • External Dimensions .......110mm W x 180mm H x 89mm D (4.3” x 7.125” x 3.5”)
  • Enclosure Ratings.............IP65 (NEMA 4X)

 

Optional Temperature Signal:

  • Sensing Element...............Various RTDs or thermistors as a 2-wire resistance output

Optional Relay Output:

  • Contact Ratings.................Form A contact (N.O.), 2 Amps @ 140 Vac, 2 Amps @ 30 Vdc
  • Relay Trip Point..................Programmable 500-15,000 ppm
  • Relay Hysteresis ................Programmable 25-500 ppm

Concealed LCD Display (Used for setting parameters):

  • Resolution ...........................1 ppm CO2
  • Size.........................................1.4” w x 0.6” h (35 mm x 15 mm)
    Alpha-numeric 2 line x 8 character
  • Backlight..............................Enable or disable via keypad

Related Products